Navigate on this page
Articles
(14 st)-
TPGL1
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...100 kPa
- Max. overload pressure
- 300 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL1-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...100 kPa
- Max. overload pressure
- 300 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL2.5
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...250 kPa
- Max. overload pressure
- 750 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL2.5-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...250 kPa
- Max. overload pressure
- 750 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL6
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...600 kPa
- Max. overload pressure
- 1500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL6-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...600 kPa
- Max. overload pressure
- 1500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL10
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1000 kPa
- Max. overload pressure
- 2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL10-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1000 kPa
- Max. overload pressure
- 2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL16
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1600 kPa
- Max. overload pressure
- 4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL16-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1600 kPa
- Max. overload pressure
- 4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL25
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...2500 kPa
- Max. overload pressure
- 6250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL25-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...2500 kPa
- Max. overload pressure
- 6250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
-
TPGL40
- Mounting
- Pipe
- Power Supply
- 12...33 V DC / 24 V AC ±15 %,< 7 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...4000 kPa
- Max. overload pressure
- 10000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m three-wire
- Media temperature
- -15…+125°C
-
TPGL40-420
- Mounting
- Pipe
- Power Supply
- 7…33 V DC, < 23 mA
- Dimensions, external (WxHxD)
- 24x55x mm
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...4000 kPa
- Max. overload pressure
- 10000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Cabel
- 1.5 m two-wire
- Media temperature
- -15…+125°C
Specifications
Protection class | IP67 |
---|---|
Storage temperature | -50…100 °C |
Weight, incl. packaging | 0.9 kg |
Media | Liquids and gases |
(Well/Pressure) connection | G 1/4 " |
Pressure connection | Outside thread |
Dynamic response time | < 2 ms, 1 ms typically |
Material sealing | FPM |