(10 st)-
SE1T24
- Force
- 100 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 4.5 min
- Auxiliary switch
- No
-
SE1TP24
- Force
- 140 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 4.5 min
- Auxiliary switch
- No
-
SE1T24S
- Force
- 100 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 4.5 min
- Auxiliary switch
- Yes
-
SE1T230
- Force
- 100 N
- Supply voltage
- 230 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 3.5 min
- Auxiliary switch
- No
-
SE1TP24S
- Force
- 140 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 4.5 min
- Auxiliary switch
- Yes
-
SE1TP230
- Force
- 140 N
- Supply voltage
- 230 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 3.5 min
- Auxiliary switch
- Yes
-
SE1T230S
- Force
- 100 N
- Supply voltage
- 230 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 3.5 min
- Auxiliary switch
- Yes
-
SE1TP230S
- Force
- 140 N
- Supply voltage
- 230 V AC ± 10 %, 50/60 Hz
- Control signal
- On/Off
- Power consumption
- 3.0 VA
- Stroke time
- 3.5 min
- Auxiliary switch
- Yes
-
SE1MP24
- Force
- 140 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- 0...10 V DC
- Power consumption
- 3.5 VA
- Stroke time
- 3.5 min
- Auxiliary switch
- No
-
SE1M24
- Force
- 100 N
- Supply voltage
- 24 V AC ± 10 %, 50/60 Hz
- Control signal
- 0...10 V DC
- Power consumption
- 3.5 VA
- Stroke time
- 4.5 min
- Auxiliary switch
- No
Specifications
Stroke | 2.5mm |
---|---|
Ambient temperature | 0…50°C |
Ambient humidity | 10...90 % RH (non-condensing) |
Storage temperature | -20…+70°C |
Storage humidity | < 95% RH |
Closing/opening time | SE1T230, SE1TP230: 210 s / SE1T24, SE1TP24: 270s |
Peak current | 24 V AC: < 0.25 A / 230 V AC: < 0.90 A |
Auxiliary switch | 250 V AC 3 A |
Cable | PVC, section 2 x 0.50 mm 2 , 2 m length |
Connection | M30 x 1.5 |
Material, casing | Matt polycarbonate, self extinguishing V0 - V1 according to UL94 |
Weight | 200 g |
Dimensions | Ø 40 x 61mm |
Protection class | IP40 |
Isolation class | II (SE1T230, SE1TP230) III (SE1T24,SE1TP24,SE1M24 e SE1MP24) |