Industrietechnik

Pressure transmitter for liquids and gases

Pressure transmitter for measurement of liquids and gases.

Articles

(14 st)
  • TPGL1 - Regin
    TPGL1
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...100 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL1-420 - Regin
    TPGL1-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...100 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL2.5 - Regin
    TPGL2.5
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...250 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL2.5-420 - Regin
    TPGL2.5-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...250 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL6 - Regin
    TPGL6
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...600 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL6-420 - Regin
    TPGL6-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...600 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL10 - Regin
    TPGL10
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...1000 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL10-420 - Regin
    TPGL10-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...1000 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL16 - Regin
    TPGL16
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...1600 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL16-420 - Regin
    TPGL16-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...1600 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL25 - Regin
    TPGL25
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...2500 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL25-420 - Regin
    TPGL25-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...2500 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL40 - Regin
    TPGL40
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 0...10v
    > 10000 Ω
    Measuring range
    0...4000 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m three-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C
  • TPGL40-420 - Regin
    TPGL40-420
    Dimensions, external (WxHxD)
    24*55* mm
    Analogue output load impedance 4...20mA
    ((Supply voltage - 7 V) / 0.02 A) Ω
    Measuring range
    0...4000 kPa
    Accuracy, resolution sensor
    0.1 % full scale %
    Accuracy, long-term stability according to IEC EN 60770-1
    Max. ±0.25 % full scale %
    Cabel
    1.5 m two-wire
    Tolerable overload
    ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
    Media temperature
    -15…+125°C

Specifications

Specifications for Pressure transmitter for liquids and gases
Power Supply 12...33 V DC / 24 V AC ±15 %,< 7 mA
Protection class IP67
Ambient temp -30…85 °C
Storage temp -50…100 °C
Weight, incl. packaging 0.9 kg
Media Liquids and gases
(Well/Pressure) connection G 1/4 "
Pressure connection Outside thread
Dynamic response time < 2 ms, 1 ms typically
Material sealing FPM

Accessories