  • TPGL1 - Regin
    TPGL1
    Working range
    0...100 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL1-420 - Regin
    TPGL1-420
    Working range
    0...100 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL2.5 - Regin
    TPGL2.5
    Working range
    0...250 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL2.5-420 - Regin
    TPGL2.5-420
    Working range
    0...250 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL6 - Regin
    TPGL6
    Working range
    0...600 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL6-420 - Regin
    TPGL6-420
    Working range
    0...600 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL10 - Regin
    TPGL10
    Working range
    0...1000 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL10-420 - Regin
    TPGL10-420
    Working range
    0...1000 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL16 - Regin
    TPGL16
    Working range
    0...1600 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL16-420 - Regin
    TPGL16-420
    Working range
    0...1600 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL25 - Regin
    TPGL25
    Working range
    0...2500 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL25-420 - Regin
    TPGL25-420
    Working range
    0...2500 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
  • TPGL40 - Regin
    TPGL40
    Working range
    0...4000 kPa
    Output signal
    0...10 V DC
    Supply voltage
    12...33 V DC / 24 V AC ±15 %
    Power consumption
    < 7 mA
  • TPGL40-420 - Regin
    TPGL40-420
    Working range
    0...4000 kPa
    Output signal
    4...20 mA
    Supply voltage
    7…33 V DC
    Power consumption
    < 23 mA
Specifications for Pressure transmitter for liquids and gases
Output signal 0...10 V DC (three-wire) or 4...20 mA (two-wire)
Pressure connection G 1/4"
Dynamic response time < 2 ms, 1 ms typically
Tolerable overload ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
Media temperature -15…+125°C
Ambient temperature -30…+85°C
Storage temperature -50…+100°C
Accuracy, characteristic line ±0.3 % full scale *
Accuracy, resolution 0.1 % full scale *
Accuracy, thermal characteristic Max. ±0.2 % full scale / 10 K *
Accuracy, long-term stability according to IEC EN 60770-1 Max. ±0.25 % full scale *
Sealing FPM
Weight 90 g
Cable length 1.5m
Protection class IP67

Product sheet

TPL105074

Mounting spacer which lowers the temperature at higher media temperatures than the sensor can handle.

DBZ-AD1