Navigate on this page
Articles
(30 st)-
STIC-PT100/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT100
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 100 Ω (0°C)
- Insertion length
- 135 mm
-
STIC-PT1000/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT1000
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 1000 Ω (0°C)
- Insertion length
- 135 mm
-
STIC-NTC1.8/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC1.8
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1800 Ω at 25°C, Beta 3416
- Insertion length
- 135 mm
- Equivalent
- TAC
-
STIC-NTC2.2/135
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC2.2
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 2252 Ω at 25°C, Beta 3977
- Insertion length
- 135 mm
- Equivalent
- Johnson Control
-
STIC-NTC10-01/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C, Beta 3977
- Insertion length
- 135 mm
- Equivalent
- Aquatrol - Johnson Control - Satchwell - Trend - Cyclon - Honeywell
-
STIC-NTC10-02/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3435
- Insertion length
- 135 mm
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
STIC-NTC10-03/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-03
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3695
- Insertion length
- 135 mm
- Equivalent
- Andover - Delta Controls - Siebe - York
-
STIC-NTC20/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC20
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 20 kΩ at 25°C, Beta 4262
- Insertion length
- 135 mm
- Equivalent
- Honeywell
-
STIC-NI1000-01/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK5000
- Insertion length
- 135 mm
- Equivalent
- Siemens - Landis & Staefa
-
STIC-NI1000-02/135Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK6180
- Insertion length
- 135 mm
- Equivalent
- Sauter
-
STIC-PT100/220Replaced by TG-D3/PT100
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT100
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 100 Ω (0°C)
- Insertion length
- 220 mm
-
STIC-PT1000/220Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT1000
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 1000 Ω (0°C)
- Insertion length
- 220 mm
-
STIC-NTC1.8/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC1.8
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1800 Ω at 25°C, Beta 3416
- Insertion length
- 220 mm
- Equivalent
- TAC
-
STIC-NTC2.2/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC2.2
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 2252 Ω at 25°C, Beta 3977
- Insertion length
- 220 mm
- Equivalent
- Johnson Control
-
STIC-NTC10-01/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3977
- Insertion length
- 220 mm
- Equivalent
- Aquatrol - Johnson Control - Satchwell - Trend - Cyclon - Honeywell
-
STIC-NTC10-02/220Sonde d'immersion avec câble
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3435
- Insertion length
- 220 mm
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
STIC-NTC10-03/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-03
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3695
- Insertion length
- 220 mm
- Equivalent
- Andover - Delta Controls - Siebe - York
-
STIC-NTC20/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC20
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 20 kΩ at 25°C, Beta 4262
- Insertion length
- 220 mm
- Equivalent
- Honeywell
-
STIC-NI1000-01/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK5000
- Insertion length
- 220 mm
- Equivalent
- Siemens - Landis & Staefa
-
STIC-NI1000-02/220
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK6180
- Insertion length
- 220 mm
- Equivalent
- Sauter
-
STIC-PT100/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT100
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 100 Ω (0°C)
- Insertion length
- 300 mm
-
STIC-PT1000/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- PT1000
- Measuring range, temp
- -30…70 °C
- Sensor element, class
- DIN Class B: ±(0.3 + .005 |T|°C)
- Nominal resistance
- 1000 Ω (0°C)
- Insertion length
- 300 mm
-
STIC-NTC1.8/300
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC1.8
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1800 Ω at 25°C, Beta 3416
- Insertion length
- 300 mm
- Equivalent
- TAC
-
STIC-NTC2.2/300
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC2.2
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 2252 Ω at 25°C, Beta 3977
- Insertion length
- 300 mm
- Equivalent
- Johnson Control
-
STIC-NTC10-01/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3977
- Insertion length
- 300 mm
- Equivalent
- Aquatrol - Johnson Control - Satchwell - Trend - Cyclon - Honeywell
-
STIC-NTC10-02/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3435
- Insertion length
- 300 mm
- Equivalent
- Carel - Evco - Eliwell - AB Industrietechnik
-
STIC-NTC10-03/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC10-03
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 10 kΩ at 25°C Beta 3695
- Insertion length
- 300 mm
- Equivalent
- Andover - Delta Controls - Siebe - York
-
STIC-NTC20/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NTC20
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 20 kΩ at 25°C, Beta 4262
- Insertion length
- 300 mm
- Equivalent
- Honeywell
-
STIC-NI1000-01/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-01
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK5000
- Insertion length
- 300 mm
- Equivalent
- Siemens - Landis & Staefa
-
STIC-NI1000-02/300Immersion sensor
- Mounting
- Immersion
- Media temp limits
- -30…70 °C
- Cable length
- 1.5 m
- Diameter, without well
- 4 mm
- Element type
- NI1000-02
- Measuring range, temp
- -30…70 °C
- Nominal resistance
- 1000 Ω at 0°C, TK6180
- Insertion length
- 300 mm
- Equivalent
- Sauter
Specifications
Protection class | IP65 |
---|---|
Bulb diameter | 4 mm |
Pressure rating immersion | PN10 |
(Well/Pressure) connection | R 1/4 " |
Terminal type | None |
Material sensor | Stainless steel, EU1.4301 (SUS304) |
Software & documentation
Product sheet
Other documentation
Accessories
DF
Mounting flange for 135 mm long sensors for mounting in ventilation ducts