TCO2CCO2
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-05CO2
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-5 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-PT100CO2 + PT100, 100 Ohm (0°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT100 (100 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-PT1000CO2 + PT1000, 1000 Ohm (0°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT1000 (1000 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC1.8CO2 + NTC 1.8, 1800 Ohm (25°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 1.8K (1800 Ω at 25 °C), B3416
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC2.2CO2 + NTC 2K2
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 2.2K (2200 Ω at 25 °C), B3977
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC10-01CO2 + NTC 10K
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25 °C), B3977
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC10-02CO2 + NTC 10, 10 kOhm (25°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25 °C), B3435
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC10-03CO2 + NTC 10, 10 kOhm (25°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25 °C), B3695
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NTC20CO2 + NTC 20, 20 kOhm (25°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 20K (2200 Ω at 25 °C), B4262
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NI1000-01CO2 + Ni1000, 1000 Ohm (0°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0 °C), TCR5000
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2C-NI1000-02CO2 + Ni1000, 1000 Ohm (0°C)
- Mounting
- Duct
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 75x77x36 mm
- Tube length
- 23 cm
- Tube diameter
- 12 mm
- Insertion length
- 60…230 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0 °C), TCR6180
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
Specifications
Appliance class | Class III |
---|---|
Protection class | IP30 |
Ambient humidity (non-condensing) | 10…90 % RH |
Storage temperature | -25…60 °C |
Mounting | Duct |
Terminal type | Screw Terminal |
Terminal wire size | 1.5 mm² |
Material, housing | Polycarbonate |
Software & documentation
Product sheet
Instructions
Other documentation
Accessories
DBZ-22
Mounting bracket for air duct transmitters