Industrietechnik
TPDL250-420 Differential pressure transmitter for liquids and gases
Differential pressure transmitter for measurement of liquids (also glycol-mixed) and gases (not ammonia).
Navigate on this page
Specifications
Power Supply | 11…33 V DC, 0,5 VA |
---|---|
Dimensions, external (WxHxD) | 40x79x mm |
Analogue output load impedance 4...20mA | <650 Ohm (at 24 V DC) |
Measuring range | 0...250 kPa |
Max. overload pressure | 1200 kPa |
Max. system pressure | 25 bar |
Accuracy, resolution sensor | ±1.3 % fs % |
Cabel | Two wire cable, 1.5 m |
Protection class | IP65 |
---|---|
Storage temperature | -15…85 °C |
Media | liquids and gases |
Pressure connection | 6 mm for copper tube |
Dynamic response time | <5 ms |
Material, housing | Stainless steel 1.4305 |
Material sensor | Ceramic material |
Software & documentation
Product sheet
Other documentation
Accessories
TPDL-NIPPEL
Nipple (R=1/8" 27 NPT) for connection of Ø 6 mm copper pipe
TPDL-R
Copper pipe, Ø 6 mm, length 30 cm