Specifications
Mounting | Pipe |
---|---|
Power Supply | 11…33 V DC, 0,5 VA |
Dimensions, external (WxHxD) | 40x79x mm |
Analogue output load impedance 4...20mA | <650 Ohm (at 24 V DC) |
Measuring range | 0...250 kPa |
Max. overload pressure | 1200 kPa |
Max. system pressure | 25 bar |
Accuracy, resolution sensor | ±1.3 % fs |
Cabel | Two wire cable, 1.5 m |
Protection class | IP65 |
---|---|
Storage temperature | -15…85 °C |
Media | liquids and gases |
Pressure connection | 6 mm for copper tube |
Dynamic response time | <5 ms |
Material, housing | Stainless steel 1.4305 |
Material sensor | Ceramic material |