Navigate on this page
Articles
(20 st)-
TUTE0111
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE0121
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE0131
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE0212
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- 0…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE0222
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -30…50 °C
- Output temperature
- 4-20 mA (2 wire)
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 1.5
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE0232
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- 0…100 °C
- Output temperature
- 4-20 mA (2 wire)
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1101
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-02 B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1102
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-02 B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1103
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-02 B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-5 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1301
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 1K8 B3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1302
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 1K8 B3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1401
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-01 B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1402
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-01 B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1501
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-03 B3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1502
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 10K-03 B3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.2
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1601
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 20K B4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE1602
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- NTC 20K B4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Accuracy, gas in air
- 0.6
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
-
TUTE1701
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- PT1000 Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE2101
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 0...10v
- >1000 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- PT100 Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Colour, cover
- White
- Colour, base
- Grey
- Power consumption
- < 1 W
-
TUTE2102
- Mounting
- Outdoor
- Dimensions, external (WxHxD)
- 75x75x36 mm
- Tube length
- 9.7 cm
- Tube diameter
- 12 mm
- Analogue output load impedance 4...20mA
- With power supply 11...17 V DC: RL <50 Ω
- Relay
- Bei Versorgungsspannung 21...30 V DC: RL < 500 Ω
- Measuring range, temp
- -20…50 °C
- Output temperature
- PT100 Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 4-20 mA (2 wire)
- Hysteresis, humidity
- ± 3% RH
- Colour, cover
- White
- Colour, base
- White
- Power supply (4...20 mA)
- Max 30 V DC, Min 11+(0.02xRL) V DC
- Power consumption
- < 1 W
Specifications
Appliance class | Class III |
---|---|
Protection class | IP65 |
Ambient humidity (non-condensing) | 10…95 % RH |
Storage temperature | -20…70 °C |
Mounting | Wall |
Weight, incl. packaging | 0.17 kg |
Accuracy, temperature | 1 K |
Cable gland | M16x1,5 |
Terminal type | Screw Terminal |
Terminal wire size | 0.75 mm² |
Material, housing | Polycarbonate |