Navigate on this page
Articles
(48 st)-
TCO2ACO2 + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-PT100CO2 + PT100, 100 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT100 (100 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-PT1000CO2 + PT1000
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT1000 (1000 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NTC1.8CO2 + NTC 1.8, 1800 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 1.8K (1800 Ω at 25 °C), B3416
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NTC2.2CO2 + NTC 2.2, 2252 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 2.2K (2252 Ω at 25 °C), B3977
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NTC10-01CO2 + NTC 10, 10 kOhm (25°C)
- Display
- No
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-NTC10-02CO2 + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3435
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NTC10-03CO2 + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3695
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NTC20CO2 + NTC 20, 20 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 20K (20 kΩ at 25 °C), B4262
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NI1000-01CO2 + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR5000
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-NI1000-02CO2 + Ni1000
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR6180
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-DCO2 + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-PT100CO2 + PT100, 100 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT100 (100 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-PT1000CO2 + PT1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT1000 (1000 Ω at 0 °C), Class B
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC1.8CO2 + NTC 1.8, 1800 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 1.8K (1800 Ω at 25 °C), B3416
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC2.2CO2 + NTC 2.2, 2252 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 2.2K (2252 Ω at 25 °C), B3977
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC10-01CO2 + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3977
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC10-02CO2 + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3435
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC10-03CO2 + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3695
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NTC20CO2 + NTC 20, 20 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 20K (20 kΩ at 25 °C), B4262
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NI1000-01CO2 + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR5000
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-NI1000-02CO2 + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR6180
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-MCO2 + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2A-D-MCO2 + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AUCO2 + °C + RH
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-PT100CO2 + RH + PT100, 100 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT100 (100 Ω at 0 °C), Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-PT1000CO2 + RH + PT1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT1000 (1000 Ω at 0 °C), Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 1.8K (1800 Ω at 25 °C), B3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 2.2K (2252 Ω at 25 °C), B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 20K (20 kΩ at 25 °C), B4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR5000
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-NI1000-02CO2 + Umidità + Ni1000
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR6180
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-DCO2 + °C + RH
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- 0-10 V
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-PT100CO2 + RH + PT100, 100 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT100 (100 Ω at 0 °C), Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-PT1000CO2 + RH + PT1000
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- PT1000 (1000 Ω at 0 °C), Class B
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 1.8K (1800 Ω at 25 °C), B3416
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 2.2K (2252 Ω at 25 °C), B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3977
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3435
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 10K (10 kΩ at 25°C), B3695
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- NTC 20K (20 kΩ at 25 °C), B4262
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR5000
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-NI1000-02CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Ni1000 (1000 Ω at 0°C), TCR6180
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-MCO2 + RH + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
-
TCO2AU-D-MCO2 + RH + °C
- Power Supply
- 24VAC/DC (22...26 V AC 50/60Hz / 15...35 V DC), VA
- Dimensions, external (WxHxD)
- 100x85x30 mm
- Display
- Yes
- Display type
- LCD
- Measuring range, temp
- 0…50 °C
- Output temperature
- Modbus
- Measuring range, humidity
- 0…100 % RH
- Output humidity
- 0-10 V
- Measuring range, gas in air
- 0…2000 ppm
- Output signal, gas in air
- 0-10 V
- Accuracy, gas in air
- < ± (50 ppm + 2 % of the measured value) (25 °C)
- Response time
- < 90 sec
- Long term stability
- Typically 20 ppm / year
- Warm-up time
- < 5 min
- Temperature dependance
- Typically 5 ppm / K
- Power consumption
- < 2.5 W
- Transformer power
- 5 VA
Specifications
Appliance class | Class III |
---|---|
Protection class | IP30 |
Ambient humidity (non-condensing) | 10…90 % RH |
Storage temperature | -25…60 °C |
Mounting | Room, Wall |
Accuracy, temperature | 0.4 K |
Terminal type | Screw Terminal |
Terminal wire size | 1.5 mm² |
Material, housing | Polycarbonate |