Industrietechnik

VFX, 2-, 3- and 3-way bypass fan coil valves

Valves, DN15-50, kvs 0.6-63, for control of heating and cooling in fan coil or chilled beams applications. The valves are intended to be used together with the thermal SE1 actuators. They are available as 2- and 3-way versions, as well as bypass versions. The valves have linear flow characteristics.

Articles

(24 st)
  • VFX210 - Regin
    VFX210
    Connection
    G 1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    0.25 m³/h
  • VFX211 - Regin
    VFX211
    Connection
    G 1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    0.4 m³/h
  • VFX212 - Regin
    VFX212
    Connection
    G 1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    0.6 m³/h
  • VFX213 - Regin
    VFX213
    Connection
    G 1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    1 m³/h
  • VFX214 - Regin
    VFX214
    Connection
    G 1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    1.6 m³/h
  • VFX235 - Regin
    VFX235
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    250 kPa
    Way
    2
    KVs direct way
    2.5 m³/h
  • VFX237 - Regin
    VFX237
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Way
    2
    KVs direct way
    4 m³/h
  • VFX239 - Regin
    VFX239
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Way
    2
    KVs direct way
    6 m³/h
  • VFX310 - Regin
    VFX310
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    0.25 m³/h
  • VFX311 - Regin
    VFX311
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    0.4 m³/h
  • VFX312 - Regin
    VFX312
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    0.6 m³/h
  • VFX313 - Regin
    VFX313
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    1 m³/h
  • VFX314 - Regin
    VFX314
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    1.6 m³/h
  • VFX335 - Regin
    VFX335
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    250 kPa
    Way
    3
    KVs direct way
    2.5 m³/h
  • VFX337 - Regin
    VFX337
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Way
    3
    KVs direct way
    4 m³/h
  • VFX339 - Regin
    VFX339
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Way
    3
    KVs direct way
    6 m³/h
  • VFX410 - Regin
    VFX410
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    0.25 m³/h
  • VFX411 - Regin
    VFX411
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    0.4 m³/h
  • VFX412 - Regin
    VFX412
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    0.6 m³/h
  • VFX413 - Regin
    VFX413
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    1 m³/h
  • VFX414 - Regin
    VFX414
    Connection
    G1/2
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN15
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    1.6 m³/h
  • VFX435 - Regin
    VFX435
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1T / SE1M
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    250 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    2.5 m³/h
  • VFX437 - Regin
    VFX437
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    4 m³/h
  • VFX439 - Regin
    VFX439
    Connection
    G3/4
    Actuator connection
    M30x1.5. SE1TP / SE1MP
    Stroke
    2.5 mm
    Nominal diameter
    DN20
    Max. diff. pressure
    80 kPa
    Media temperature
    2…95 °C
    Way
    3 (con bypass)
    KVs direct way
    6 m³/h

Specifications

Specifications for VFX, 2-, 3- and 3-way bypass fan coil valves
Application Cooling, Heating, Fan coil
Pressure rating PN16
Connection types BSP externally threaded according to ISO 228/1
Flow characteristics Linear
Leakage 0.0 % of Kvs ()
Media Glycol-mixed water (max. 40 % glycol), Hot water, Cold water
Closing direction When stem is pulled outward
Media temperature 2…95 °C
Body Brass CW614N
Seat Brass CW614N
Plug PA + GF
Stem PA + GF
O-rings FKM
Stuffing box PPO + GP
Spring Stainless steel

Accessories