CO2 transmitter, room mounting
This series with automatic calibration sets new standards in CO2 measurement for HVAC applications. It combines the measurement of the carbon dioxide level, temperature and relative humidity. Models with or without display are available.
Navigate on this page
Articles
(48 st)-
-
TCO2A-PT100CO2 + PT100, 100 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-PT1000CO2 + PT1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-NTC1.8CO2 + NTC 1.8, 1800 Ohm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2A-NTC2.2CO2 + NTC 2.2, 2252 Ohm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-NTC10-01CO2 + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-NTC10-02CO2 + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-NTC10-03CO2 + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.25 °C
-
TCO2A-NTC20CO2 + NTC 20, 20 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-NI1000-01CO2 + Ni1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2A-NI1000-02CO2 + Ni1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
-
TCO2A-D-PT100CO2 + PT100, 100 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-D-PT1000CO2 + PT1000, 1000 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-D-NTC1.8CO2 + NTC 1.8, 1800 Ohm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2A-D-NTC2.2CO2 + NTC 2.2, 2252 Ohm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-D-NTC10-01CO2 + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-D-NTC10-02CO2 + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2A-D-NTC10-03CO2 + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.25 °C
-
TCO2A-D-NTC20CO2 + NTC 20, 20 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2A-D-NI1000-01CO2 + Ni1000, 1000 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2A-D-NI1000-02CO2 + Ni1000, 1000 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
-
-
TCO2AUCO2 + °C + RH
- Display
- -
- Output signal
- 0…10 V + 0…10 V + 0…10 V
- Accuracy, temperature
- ± 0.4 °C
-
TCO2AU-PT100CO2 + RH + PT100, 100 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-PT1000CO2 + RH + PT1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2AU-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.25 °C
-
TCO2AU-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2AU-NI1000-02CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Display
- -
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2AU-DCO2 + °C + RH
- Display
- X
- Output signal
- 0…10 V + 0…10 V + 0…10 V
- Accuracy, temperature
- ± 0.4 °C
-
TCO2AU-D-PT100CO2 + RH + PT100, 100 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-D-PT1000CO2 + °C + RH
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-D-NTC1.8CO2 + RH + NTC 1.8, 1800 Ohm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2AU-D-NTC2.2CO2 + RH + NTC 2.2, 2252 Ohm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-D-NTC10-01CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-D-NTC10-02CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.3 °C
-
TCO2AU-D-NTC10-03CO2 + RH + NTC 10, 10 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.25 °C
-
TCO2AU-D-NTC20CO2 + RH + NTC 20, 20 kOhm (25°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.2 °C
-
TCO2AU-D-NI1000-01CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
TCO2AU-D-NI1000-02CO2 + RH + Ni1000, 1000 Ohm (0°C)
- Display
- X
- Output signal
- 0…10 V + 0…10 V + ohm
- Accuracy, temperature
- ± 0.5 °C
-
-
Specifications
Supply voltage | 24 V AC ±10 %, 50...60 Hz / 15...35 V DC |
---|---|
Working range, CO 2 | 0…2000ppm |
Working range, temperature | 0…50°C |
Working range, humidity | 10…90% RH |
Power consumption | < 2.5 W |
Energy consumption | < 0.5 Wh |
Transformer power | ≥ 5 VA |
Accuracy, CO 2 | < ± (50 ppm + 2 % of the measured value) (25 °C) |
Accuracy, humidity | ±3 % RH (20°C) |
Mounting | Room |
Dimensions | 100 x 85 x 30.5mm |
Protection class | IP30 |
CO 2 | 0...10 V DC referring to 0...2000 ppm |
Temperature | 0...10 V DC referring to 0…50°C |
Humidity | 0...10 V DC referring to 0...100 % RH |