Humidity and temperature transmitter for room mounting, IP30

Articles

(24 st)
  • TTUA - Regin
    TTUA
    RH + °C
    Display
    -
    Output signal
    0...10 V + 0…10 V
    Accuracy, temperature
    ± 0.4 °C
  • TTUA-PT100 - Regin
    TTUA-PT100
    RH + PT100, 100 Ohm (0°C)
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-PT1000 - Regin
    TTUA-PT1000
    RH + PT1000, 1000 Ohm (0°C)
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-NTC1.8 - Regin
    TTUA-NTC1.8
    RH + NTC 1.8, 1800 Ohm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-NTC2.2 - Regin
    TTUA-NTC2.2
    RH + NTC 2.2, 2252 Ohm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-NTC10-01 - Regin
    TTUA-NTC10-01
    RH + NTC 10, 10 kOhm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-NTC10-02 - Regin
    TTUA-NTC10-02
    RH + NTC 10, 10 kOhm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-NTC10-03 - Regin
    TTUA-NTC10-03
    RH + NTC 10, 10 kOhm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,25 °C
  • TTUA-NTC20 - Regin
    TTUA-NTC20
    RH + NTC 20, 20 kOhm/25°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-NI1000-01 - Regin
    TTUA-NI1000-01
    RH + Ni1000, 1000 Ohm/0°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-NI1000-02 - Regin
    TTUA-NI1000-02
    RH + Ni1000, 1000 Ohm/0°C
    Display
    -
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-D - Regin
    TTUA-D
    RH + °C
    Display
    X
    Output signal
    0...10 V + 0…10 V
    Accuracy, temperature
    ± 0.4 °C
  • TTUA-D-PT100 - Regin
    TTUA-D-PT100
    RH + PT100, 100 Ohm/0°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-D-PT1000 - Regin
    TTUA-D-PT1000
    RH + PT1000, 1000 Ohm (0°C)
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-D-NTC1.8 - Regin
    TTUA-D-NTC1.8
    RH + NTC 1.8, 1800 Ohm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-D-NTC2.2 - Regin
    TTUA-D-NTC2.2
    RH + NTC 2.2, 2252 Ohm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-D-NTC10-01 - Regin
    TTUA-D-NTC10-01
    RH + NTC 10, 10 kOhm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-D-NTC10-02 - Regin
    TTUA-D-NTC10-02
    RH + NTC 10, 10 kOhm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,3 °C
  • TTUA-D-NTC10-03 - Regin
    TTUA-D-NTC10-03
    RH + NTC 10, 10 kOhm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,25 °C
  • TTUA-D-NTC20 - Regin
    TTUA-D-NTC20
    RH + NTC 20, 20 kOhm/25°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,2 °C
  • TTUA-D-NI1000-01 - Regin
    TTUA-D-NI1000-01
    RH + Ni1000, 1000 Ohm/0°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-D-NI1000-02 - Regin
    TTUA-D-NI1000-02
    RH + Ni1000, 1000 Ohm/0°C
    Display
    X
    Output signal
    0...10 V + ohm
    Accuracy, temperature
    ± 0,5 °C
  • TTUA-M - Regin
    TTUA-M
    RH + C°
    Display
    -
    Output signal
    Modbus
    Accuracy, temperature
    ± 0.4 °C
  • TTUA-D-M - Regin
    TTUA-D-M
    RH + °C
    Display
    X
    Output signal
    Modbus
    Accuracy, temperature
    ± 0.4 °C
Specifications for Humidity and temperature transmitter for room mounting, IP30
Supply voltage 24 V AC ±10 % / 15…35 V DC
Power consumption < 1 W
Transformer power ≥ 2 VA
Working range, temperature 0…50°C
Working range, humidity 0…100% RH
Accuracy, humidity ±3 % RH at 20°C
Mounting Room
Dimensions 100 x 85 x 30.5mm
Protection class IP30

Product sheet

Other documentation